Send Message
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Hebei Paris International  Trading Co.,LTD

Sales & Support:

Home ProductsSpecialised Pipe And Fittings

316L Thermal Specialised Pipe And Fittings , 600mm Square Manhole Cover

I'm Online Chat Now

316L Thermal Specialised Pipe And Fittings , 600mm Square Manhole Cover

316L Thermal Specialised Pipe And Fittings , 600mm Square Manhole Cover
316L Thermal Specialised Pipe And Fittings , 600mm Square Manhole Cover 316L Thermal Specialised Pipe And Fittings , 600mm Square Manhole Cover

Large Image :  316L Thermal Specialised Pipe And Fittings , 600mm Square Manhole Cover

Product Details:
Place of Origin: Cangzhou ,Hebei Pro ,China
Brand Name: OEM
Certification: CNAS ,PED ,CE,ISO
Model Number: DN15-DN5000
Payment & Shipping Terms:
Minimum Order Quantity: 1pc
Price: Negiotion
Packaging Details: Carton Box, Pallet , or Plywood Case No Unacceptable Packaging Material or Bamboo Products been Used as Packing
Delivery Time: 5-7 days
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 10000 ton/month Specialised Pipe And Fittings
Detailed Product Description
Dimensions: Customer Required Model: Sandard/Non-standard
Price: Negiotion Application Temperature: Application Temperature
Head Code: Square OEM/ODM: Allowed
Working Pressure: Normal Shape: Equal
Payment: T/T Port: Tianjin
Highlight:

316L Specialised Pipe And Fittings

,

316L square manhole cover

,

600mm Specialised Pipe And Fittings

Products  decription :

Rectangular thermal insulation square manual manhole Specialised Pipe And Fittings

 

what is Manhole:

The manhole is a safety emergency ventilation device installed on the top of the storage tank. It is usually used in conjunction with fire extinguishers and mechanical breathing valves. It can prevent accidents from damaging the storage tank when sudden overpressure or vacuum is caused by accidents. It is a safety device to protect the storage tank, and it is a safety device to protect the storage tank. It is especially suitable for the vaulted atmospheric tank with nitrogen topped by the storage material. It has the advantages of constant pressure discharge, constant pressure suction, flexible opening and closing, safe fire resistance, compact structure, good sealing performance, safety and reliability.

Manholes are divided into emergency pressure relief manholes, explosion-proof fire-resisting breathing manholes, tank top manholes, tank wall manholes and cored manholes.

Manholes are generally made of 304,316L stainless steel plate or carbon steel.

Structure
Manholes have been shaped products, usually 600mm in diameter. The center of the manhole is generally 750mm from the floor. It is convenient for the staff to enter and exit the oil tank or ventilate during installation, cleaning and maintenance.

The manhole of the non-metal oil tank is set on the top of the tank, and the manhole of the metal oil tank is set on the bottom plate of the tank wall. Most of them are round holes with a diameter of 600mm, with a center distance of 750mm from the bottom plate. They are used for tank cleaning or maintenance personnel to enter and exit the tank. They are also called gates. Use manholes for lighting and ventilation at all times during maintenance and cleaning of oil tanks. Vertical oil tanks have 1 to 2 manholes when the capacity is below 5000m3, and 2 manholes for those above 5000m3. The installation of the manhole should be no more than 90° away from the oil inlet and outlet pipelines. When only one manhole is provided, it should be placed on the opposite side of the light-transmitting hole on the top of the tank; when two manholes are provided, one of them is located on the opposite side of the light-transmitting hole, and the other should be separated from the first manhole by at least 90 °.

One manhole should be located near the right side of the oil inlet and outlet pipes, and try to make the manhole face the closed door of the tank chamber so as to facilitate the entry and exit of the oil tank and the ventilation pipe.

Since the manhole is installed on the bottom ring of the oil tank, leakage prevention is particularly important. It is required that the joint surface of the two flanges must be flat and free of twisting. Reinforcing plates and flanges should be cut on the whole steel plate without splicing. The flange and cover plate are processed with sealing rings, so special attention should be paid to protection during construction. 3mm thick asbestos rubber gasket is used for sealing, no cracks are allowed. When installing the manhole cover to tighten the bolts, force evenly at diagonal angles to prevent deformation of the manhole cover.

 

Installation and maintenance
Because the manhole is located in the lower part of the oil tank, the manhole is subject to great liquid pressure. In order to prevent leakage, the installation quality of the manhole must be strictly required. The flanges and cover plates are processed with sealing water lines, which should be protected during construction to avoid oil leakage during use. Make a mark every time the manhole is removed to avoid dislocation during reinstallation and affect tightness. When installing the nuts on the manhole cover, apply force evenly in pairs to prevent oil leakage caused by deformation of the cover or uneven force.

316L Thermal Specialised Pipe And Fittings , 600mm Square Manhole Cover 0 

316L Thermal Specialised Pipe And Fittings , 600mm Square Manhole Cover 1

316L Thermal Specialised Pipe And Fittings , 600mm Square Manhole Cover 2

 

Contact Details
Hebei Paris International Trading Co.,LTD

Contact Person: Mr. Terry ding

Tel: 18330713028

Fax: 86-317-6013869

Send your inquiry directly to us (0 / 3000)